Release Notes#
Version 2.0.1 (Aug 15, 2025)#
Summary#
Delivers general CLI command improvements across all variants and fixes an issue where stored PTI configuration was not applied on boot.
Package Update Matrix#
Package | Added (concise) | Fixed (concise) | Notes |
|---|---|---|---|
B | CLI improvements | PTI config applied on boot | None |
D | CLI improvements | PTI config applied on boot | None |
E | CLI improvements | PTI config applied on boot | None |
F | CLI improvements | None | None |
Notes#
None.
Common Changes#
Added Features#
General improvements for CLI commands.
Fixed Issues#
(Packages B, D, E) Stored PTI configuration would not be applied on boot.
Variant-Specific Changes#
None.
Known Issues and Limitations#
Common#
VUART on series 2 devices may stop working after a reset of the the target device. (Unchanged)
Variant-Specific#
None.
Version 2.0.0 (Jul 07, 2025)#
Summary#
Introduces WinUSB driver mode and PCODE/HSS support across all variants and updates the bootloader to 0.13.0 for the E variant.
Package Update Matrix#
Package | Added (concise) | Fixed (concise) | Notes |
|---|---|---|---|
B | WinUSB support, PCODE/HSS support | None | None |
D | WinUSB support, PCODE/HSS support | None | None |
E | WinUSB support, PCODE/HSS support, Bootloader 0.13.0 | CTUNE read fix | None |
F | WinUSB support, PCODE/HSS support | None | None |
Notes#
When upgrading from any version earlier than 2.0.0 to 2.0.0 or later, the adapter automatically switches to WinUSB. This changes the USB PID and can affect setups that depend on the previous PID. On Windows 7 or earlier, install the latest SEGGER J-Link package with "Legacy drivers" enabled before updating.
If needed, the mode can be changed back to SEGGER using either one of:
Simplicity Commander:
commander adapter drivermodeor GUI.Admin console: The
sys drivermodecommand.SEGGER J-Link Configurator.
Common Changes#
Added Features#
WinUSB support.
PCODE and HSS support.
Fixed Issues#
None.
Variant-Specific Changes#
Package E#
Added:
Bootloader updated to version 0.13.0.
Fixed:
Reading CTUNE value could return garbage if no value was set in the radio board.
Known Issues and Limitations#
Common#
VUART on series 2 devices may stop working after a reset of the the target device. (Unchanged)
Variant-Specific#