Plugin Commands: PYD-1698 Occupancy Sensor CLI
Detailed Description
Command line interface for changing operational parameters of the PYD-1698 occupancy sensor at runtime.
Macro Definition Documentation
#define EMBER_AF_DOXYGEN_CLI_COMMAND_PLUGIN_OCCUPANCY_PYD1698_CLI_PLUGIN_OCCUPANCY_PYD1698_CLI_NEW_STATE |
plugin occupancy-pyd1698-cli newState [newState:1]
-
Simulate a transition to a new occupancy state
- newState - INT8U
#define EMBER_AF_DOXYGEN_CLI_COMMAND_PLUGIN_OCCUPANCY_PYD1698_CLI_PLUGIN_OCCUPANCY_PYD1698_CLI_READ |
plugin occupancy-pyd1698-cli read
- Read and print the configuration status of the occupancy sensor.
#define EMBER_AF_DOXYGEN_CLI_COMMAND_PLUGIN_OCCUPANCY_PYD1698_CLI_PLUGIN_OCCUPANCY_PYD1698_CLI_SET_BLIND_TIME |
plugin occupancy-pyd1698-cli set-blind-time [value:1]
-
Set the blind time configuration bits to the given value
- value - INT8U
#define EMBER_AF_DOXYGEN_CLI_COMMAND_PLUGIN_OCCUPANCY_PYD1698_CLI_PLUGIN_OCCUPANCY_PYD1698_CLI_SET_FILTER_SOURCE |
plugin occupancy-pyd1698-cli set-filter-source [value:1]
-
Set the filter source configuration bits to the given value
- value - INT8U
#define EMBER_AF_DOXYGEN_CLI_COMMAND_PLUGIN_OCCUPANCY_PYD1698_CLI_PLUGIN_OCCUPANCY_PYD1698_CLI_SET_OPERATION_MODE |
plugin occupancy-pyd1698-cli set-operation-mode [value:1]
-
Set the operation mode configuration bits to the given value
- value - INT8U
#define EMBER_AF_DOXYGEN_CLI_COMMAND_PLUGIN_OCCUPANCY_PYD1698_CLI_PLUGIN_OCCUPANCY_PYD1698_CLI_SET_PULSE_COUNTER |
plugin occupancy-pyd1698-cli set-pulse-counter [value:1]
-
Set the pulse counter configuration bits to the given value
- value - INT8U
#define EMBER_AF_DOXYGEN_CLI_COMMAND_PLUGIN_OCCUPANCY_PYD1698_CLI_PLUGIN_OCCUPANCY_PYD1698_CLI_SET_THRESHOLD |
plugin occupancy-pyd1698-cli set-threshold [value:1]
-
Set the threshold configuration bits to the given value
- value - INT8U
#define EMBER_AF_DOXYGEN_CLI_COMMAND_PLUGIN_OCCUPANCY_PYD1698_CLI_PLUGIN_OCCUPANCY_PYD1698_CLI_SET_WINDOW_TIME |
plugin occupancy-pyd1698-cli set-window-time [value:1]
-
Set the window time configuration bits to the given value
- value - INT8U